* qt_sink: add some warning on its usage
* qt_sink: add some warning on its usage - fix
---------
Co-authored-by: Benoit FANCHON <bfanchon@nanoxplore.com>
* Removes special format handling for fmt. Regains test compatibility with fmt
1.10.0.
fixes#2735
* reverted std::vector back to filename_t and used pointer to array start likewise as fmt's implementation uses
* calc_filename buffer increase softened, exception is throw if buffer exceeds 4k, filename parameter renamed to match intend.
* calc_filetime based on std::put_time for simpler implementation
* Fix stdout_sink_base::log's behavior inconsistency
It will flush every time when it if not defined _WIN32, but not in
Windows family.
We viewed the commit #48d4ed9 for fixing issue #1675 .
It seems missing this flushing operation in mistake.
* Use fflush at all operating system
* Remove redundant fflush from stdout_sink_base
---------
Co-authored-by: scc <scc@teamt5.org>
From the systemd.journal-fields the TID is a user defined
field passed directly from the clients and stored in the
journal. Adding the arguement in the journal send to support
that storage option in the journal.
* dup_filter_sink adds parameters to enable setting the level of skipped logs
* rename the param name 'level' to 'notification_level'
Co-authored-by: zhuyadong <zhuyadong@kedacom.com>
There can only be one instance in the whole program, so programs that use the
Mongo sink and also separately use MongoCXX may have problems if the Mongo sink
owns the instance. MongoCXX recommends that the main application manage its own
instance so configuration parameters can be passed to the constructor:
http://mongocxx.org/api/current/classmongocxx_1_1instance.html
However, this commit is not a breaking change. If no instance has been created
at construction time, the Mongo sink will still create and own the instance.
Filtering to a certain log level or above, a useful operation, can now be done
with an integer comparison as opposed to comparing to a list of strings in the
database query.